MRT(P.O.) = AUMC(po)/AUC(po) = 937.89/116.74 = 8.03 hr
MAT (P.O.) = MRT(po) - MRT(iv) = 8.034 - 7.03 = 1.01 hr
kel' = 1/MRT(iv) = 1/7.03 = 0.142 hr-1 [Assuming one compartment model, etc.]
ka' = 1/MAT(po) = 1/1.007 = 0.993 hr-1 [Assuming first order absorption]
CL(I.V.) = Dose/AUC(iv) = 150/73.91 = 2.03 L/hr
Vss(I.V.) = CL(iv) x MRT(iv) = 2.03 x 7.03 = 14.3 L
F(P.O.) = (AUC(po) x Dose(iv))/(AUC(iv) x Dose(po)) = (116.74 x 150) / (73.91 x 300) = 0.79